Products > Pressure > Electronic pressure controller for gases |
| |
|
|
|
|
| |
Electronic pressure controller for gases
with integrated flow measurement |
| |
|
|
|
|
| |
Pressure and flow in a single device |
| |

|
| |
red-y smart pressure controller GSP |
| |
|
| |
The new electronic red-y smart pressure controllers combine the reliable technology our of thermal mass flow controllers with electronic pressure control.
The devices automatically control a predefined process pressure and at the same time measure and/or limit the flow rate.
On-the-fly switching between pressure control and flow control offers maximum flexibility. |
| |
|
| |
1 device – 3 functions |
| |
The pressure controller combines three functions:
– Pressure controller
– Pressure controller with flow measurement/limitation
– Flow controller with pressure measurement |
| |
|
| |
Instrument versions: |
| |
– Integrated pressure control: Accuracy:± 0.5 % of full scale
– Integrated back pressure control: Accuracy:± 0.5 % of full scale
– Pressure control with external pressure transmitters
– Pressure controller with gas mixer function |
| |
|
| |
More information: |
| |
» Instrument types
» Technical overview
» Accessories |
» Documentation, Downloads
» Online Quotation
» Contact |
| |
|
 |
|
| |
INSTRUMENT TYPES |
| |
 |
red-y smart
pressure controller GSP
Electronic pressure controller with integrated flow measurement |
| |
|
| |
 |
red-y smart
back pressure controller GSB
Electronic back pressure controller with integrated flow measurement |
| |
|
 |
|
| |
TECHNICAL
OVERVIEW |
| |
Instrument versions flow |
Standard |
Accuracy: ± 1.0 % of full scale
Turndown ratio: 1 : 50 |
| |
|
Hi-Performance |
Accuracy: ± 0.3 % of full scale + ± 0.5% of reading
Turndown ratio: 1 : 100 |
| |
Instrument versions pressure |
Pressure control |
Accuracy: ± 0.5 % of full scale |
| |
|
Back pressure control |
Accuracy: ± 0.5 % of full scale |
| |
|
|
Differential pressure controller according to customer specifications |
| |
|
| |
Performance data |
Media (real gas calibration) |
Air, O2, N2, He, Ar, CO2, H2, CH4, C3H8
Other gases and gas mixtures on request |
| |
|
Response time |
50
ms |
| |
|
Repeatability |
± 0,2%
of full scale |
| |
|
Longterm stability |
< 1% of measured value / year |
| |
|
Power supply |
24 Vdc (18 – 30 Vdc), 15 Vdc on request |
| |
|
Current consumption |
max. 250mA |
| |
|
Temperature |
0 – 50°C |
| |
|
Materials |
Anodized aluminium, optional stainless steel electropolished |
| |
|
Seals |
FKM, optional
EPDM |
| |
|
Pressure sensitivity |
< 0.2% / bar of reading (typical N2) |
| |
|
Temperature sensitivity |
< 0.025% FS measuring range type / °C |
| |
|
| |
Measuring ranges |
|
|
| |
Flow (Air) |
Type |
Measuring range (Air), full scale freely selectable |
| |
pressure GSP |
GSX-A |
from 0 ... 25 mln/min |
to 0 ... 600 mln/min |
| |
back pressure GSB |
GSX-B |
from 0 ... 600 mln/min |
to 0 ... 6000 mln/min |
| |
|
GSX-C |
from 0 ... 6 ln/min |
to 0 ... 60 ln/min |
| |
|
GSX-D |
from 0 ... 60 ln/min |
to 0 ... 450 ln/min |
| |
Pressure |
Full scale gauge pressure |
0.5 bar ü, 1 bar ü, 2 bar ü, 5 bar ü, 10 bar ü |
| |
|
Full scale absolute pressure |
1.2 bar a, 2 bar a, 5 bar a, 10 bar a |
| |
|
| |
Integration |
Output signals: |
|
| |
|
- Analog
|
0..20 mA,
4..20 mA, 0..5 V, 1..5 V, 0..10 V, 2..10 V
(for actual value flow only) |
| |
|
- Digital |
RS-485; Modbus
RTU (Slave); Lab View-VI‘s available
Option: ProfiBus DP-V0,
DP-V1
(for pressure & flow) |
| |
|
Process connection |
G¼¨ female less than 60 ln/min, G½¨ female less than 450 ln/min |
| |
|
Inlet section |
non required |
| |
|
Electrical connection |
Sub D plug, 9 pole |
| |
|
Mounting orientation |
Any orientation (horizontal only above 5 bar) |
| |
|
| |
Safety |
Test pressure |
16 bar a |
| |
|
Leak rate |
< 1 x 10-6 mbar l/s He |
| |
|
Environmental protection |
IP-50 |
| |
|
EMC |
EN 61326-1 |
| |
|
 |
|
| |
ACCESSORIES |
| |
 |
Free
Software 'get red-y'
– View flow rate and temperature
– Change setpoints
– Select measured gas or gas mixtures
– Graphical display of measured data
– Adjusting control parameters
– Monitor operating state
– Totalizer
– Optional: Datalogging, gasmixer
– Runs on all computers with Windows XP/Vista/7
» More
Information |
| |
|
| |
 |
Display and Control Device PCU-10
– Display of the gas flow set value for each connected meter
and controller
– Display of the gas flow actual value for each connected meter
and controller
– Specification and storage of set values
– Storage of up to 12 different gas mixtures as recipes
– Total flow meter for each connected meter and controller
– Specification of minimum and maximum limit values with red alarm
display on reaching the limits
– Gas mixer with up to 12 recipes
– Display of the instrument temperature of the connected meter
and controller
– Mixed operation with Vögtlin and BHT devices possible
– No additional mains adaptor required
– Control of the connected meter and controller with a PC by means
of PDM-U connection cable
– Use of the get red-y software on a PC for direct configuration
of the meter and controller
» More
Information: www.red-y.com |
| |
|
| |
|
Cables
& Modules
Cables and Modules for the Thermal Mass Flow Meters and Mass Flow Controllers
'red-y smart series'.
» More
Information: www.red-y.com |
| |
|
 |
|
| |
DOWNLOADS |
| |
Document |
Type/Size |
| |
Datasheet
red-y smart pressure controller |
PDF/500kB |
| |
Data
Sheet
Software 'get-red-y' |
PDF/100kB |
| |
Data
Sheet
Readout System PCU-10 |
PDF/500kB |
| |
Data
Sheet
Cables, Modules & Supply |
PDF/100kB |
| |
Data Sheet Fittings |
PDF/300kB |
| |
CAD 3D models |
|
| |
|
| |
» More
Downloads |
|
| |
|
 |
|
| |
Vögtlin Instruments AG – flow
technology – Phone +41 61 756 63 00 – Last Update:
13.01.2012 |